FUGrant

FU on a Grant heat pump: High pressure switch is operating

Short answer

On a Grant heat pump, FU means: High pressure switch is operating. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manual says: High pressure switch is operating.

Part involved: high pressure switch / water flow.

When it shows: Detected by heat pump/controller PCB; error reset type printed as 'Manual'.

Likely causes:

  • Outside air recirculation.
  • Clogged water circuit (low flow rate).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: No.

Manual reset: Manual: engineer presses - and + on the remote controller together for 3 s, or Reset SW on the Terminal PCB (mains OFF/ON possible but not recommended).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Check the outdoor unit air inlet and fan outlet are not blocked by leaves, snow, ice or stored objects.
  • Check the heating system pressure gauge (if one is fitted) and report a low reading to your installer; make sure the filling loop valves are closed.
  • Grant advises homeowners NOT to reset Aerona3 fault codes themselves - leave the reset to the engineer.

What the engineer will check

  • Check temperature difference of outgoing/return water via Monitor display function - a large difference means flow rate is too low.
  • Make sure the position doesn't block the air inlet and outlet.
  • Remove water-circuit blockage then restart.

Who to ask for: Grant-trained (G1) heat pump engineer.

What you might notice

What owners and engineers report

11 owner and engineer reports mention this.

  • No heating on the Aerona³ R32: 5 reports
  • Radiators cold on the Aerona³ R32: 4 reports
  • Keeps stopping / cutting out on the Aerona³ R32: 1 report
  • No heating on the Aerona³ (R410A): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026