SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Grant
E8Grant

E8 on a Grant heat pump: Remote controller communication error

Short answer

On a Grant heat pump, E8 means: Remote controller communication error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manual says: Remote controller communication error.

Part involved: remote controller wiring / controller PCB.

When it shows: Detected by heat pump/controller PCB; error reset type printed as 'Auto'.

Likely causes:

  • Incorrect remote controller wiring.
  • Loose interface connection cable or contacts.
  • Controller PCB faulty.

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Auto: resets automatically once conditions return to normal (if the heat pump has stopped it may need a manual reset).

Manual reset: Engineer: press - and + on the remote controller together for 3 s, or press Reset SW on the Terminal PCB.

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Grant advises homeowners NOT to reset Aerona3 fault codes themselves - leave the reset to the engineer.

What the engineer will check

  • Check loose cable connections and contacts; correct wiring and restart.
  • Otherwise replace controller PCB.

Who to ask for: Grant-trained (G1) heat pump engineer.

Certification: Competent electrician/heating engineer for mains electrical and PCB work (safe isolation; capacitor discharge).

What you might notice

What owners and engineers report

9 owner and engineer reports mention this.

  • Controller / thermostat problem on the Aerona³ R32: 9 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026