C7 on a Grant heat pump: Controller PCB serial error
Short answer
On a Grant heat pump, C7 means: Controller PCB serial error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 2 sources
What it means
The manual says: Controller PCB serial error.
Part involved: main PCB - controller PCB cable.
When it shows: Detected by heat pump/controller PCB; error reset type printed as 'Auto'.
Likely causes:
- Mis-wiring or poor ('rare') contact on Main PCB - Controller PCB connecting cable.
- Controller PCB faulty.
- Main PCB faulty.
- Earth wire not properly installed.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: Auto: resets automatically once conditions return to normal (if the heat pump has stopped it may need a manual reset).
Manual reset: Engineer: press - and + on the remote controller together for 3 s, or press Reset SW on the Terminal PCB.
What you can check
- Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
- Grant advises homeowners NOT to reset Aerona3 fault codes themselves - leave the reset to the engineer.
What the engineer will check
- Check wiring connection and contact; correct mis-wiring and restart.
- Otherwise replace Controller PCB or Main PCB.
- Check earth wire is properly installed.
Who to ask for: Grant-trained (G1) heat pump engineer.
Certification: Competent electrician/heating engineer for mains electrical and PCB work (safe isolation; capacitor discharge).
What you might notice
What owners and engineers report
7 owner and engineer reports mention this.
- No heating on the Aerona³ R32: 5 reports
- Intermittent fault on the Aerona³ R32: 1 report
- No heating on the Aerona³ (R410A): 1 report
Sources
- Grant Aerona³ Air to Water High Efficiency Heat Pump Range - Installation and Servicing Instructions (UK DOC 0136) ↗ · Rev 2.4 · page 55 (DOC 0154: 54) · Reviewed 23 September 2026
- Grant UK Aerona³ Air to Water High Efficiency Heat Pump Range - Installation and Servicing Instructions (UK DOC 0109) ↗ · Rev 1.1 · page 54 (IRL DOC 0001: s11.4-11.5, printed pp55-57) · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026