C4 on a Grant heat pump: Rise of temperature (above 110°C) of Main PCB

Short answer

On a Grant heat pump, C4 means: Rise of temperature (above 110°C) of Main PCB. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manual says: Rise of temperature (above 110°C) of Main PCB.

Part involved: main PCB temperature.

When it shows: Detected by heat pump/controller PCB; error reset type printed as 'Manual'.

Likely causes:

  • Mis-installation (blockage of air inlet & outlet).
  • Main PCB temperature sensor / Main PCB faulty.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: No.

Manual reset: Manual: engineer presses - and + on the remote controller together for 3 s, or Reset SW on the Terminal PCB (mains OFF/ON possible but not recommended).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Check the outdoor unit air inlet and fan outlet are not blocked by leaves, snow, ice or stored objects.
  • Grant advises homeowners NOT to reset Aerona3 fault codes themselves - leave the reset to the engineer.

What the engineer will check

  • Check the place of installation for blockage of air inlet & outlet; ensure installation position avoids blockage.
  • Main PCB should be replaced.

Who to ask for: Grant-trained (G1) heat pump engineer.

Certification: Competent electrician/heating engineer for mains electrical and PCB work (safe isolation; capacitor discharge).

What you might notice

What owners and engineers report

7 owner and engineer reports mention this.

  • No heating on the Aerona³ R32: 5 reports
  • Keeps stopping / cutting out on the Aerona³ R32: 1 report
  • No heating on the Aerona³ (R410A): 1 report