A5 on a Grant heat pump: Abnormal revolution of compressor

Short answer

On a Grant heat pump, A5 means: Abnormal revolution of compressor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manual says: Abnormal revolution of compressor.

Part involved: compressor / pump / water circuit / fuse CF6.

When it shows: Detected by heat pump/controller PCB; error reset type printed as 'Manual'.

Likely causes:

  • Unreasonable operation under overload (blocked air inlet/outlet, excess gas).
  • Drop of power voltage (incl. during operation).
  • Fuse CF6 blown.
  • Clogged water: pump and/or water circuit.
  • Momentary stop of power (lightning).
  • Compressor or Main PCB faulty.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: No.

Manual reset: Manual: engineer presses - and + on the remote controller together for 3 s, or Reset SW on the Terminal PCB (mains OFF/ON possible but not recommended).

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Check the outdoor unit air inlet and fan outlet are not blocked by leaves, snow, ice or stored objects.
  • Check the heating system pressure gauge (if one is fitted) and report a low reading to your installer; make sure the filling loop valves are closed.
  • Check the heat pump isolator switch and the consumer-unit breaker/RCD for the heat pump are ON (do not repeatedly reset a tripping breaker).
  • Grant advises homeowners NOT to reset Aerona3 fault codes themselves - leave the reset to the engineer.

What the engineer will check

  • Check the place of installation for blockage of air inlet & outlet.
  • Check excess gas.
  • Check power voltage (230V) including during operation.
  • Check Fuse CF6 continuity by tester; if blown replace Main PCB.
  • Check the pump and water circuit; remove blockage then restart.
  • Otherwise replace compressor.

Who to ask for: Grant-trained (G1) heat pump engineer.

Certification: F-gas certified refrigeration engineer (refrigerant circuit work).

What you might notice

What owners and engineers report

7 owner and engineer reports mention this.

  • No heating on the Aerona³ R32: 5 reports
  • Keeps stopping / cutting out on the Aerona³ R32: 1 report
  • No heating on the Aerona³ (R410A): 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.