19 on a Grant Aerona³ R32: No communication with heat pump module

Short answer

On a Grant heat pump, 19 means: No communication with heat pump module. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • No communication with heat pump module.
  • Too often no flow detected.

Part involved: Modbus link wiring centre - heat pump; Smart flow sensor / heat pump.

When it shows: Alert passed from the Smart Controller to the wired room thermostat display; also shown in the Smart Controller alarm list Alert passed from the Smart Controller to the wireless room thermostat display; also shown in the Smart Controller alarm list.

Likely causes:

  • Heat pump has no power / isolator OFF.
  • Modbus wiring connection or polarity incorrect.
  • Smart flow sensor not connected correctly.
  • Smart flow sensor not configured correctly.
  • Heat pump not working correctly.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated.

Manual reset: Not stated.

What you can check

  • Note the exact code shown on the controller display and tell your installer or Grant-trained engineer.
  • Tap the alarm icon on the Smart Controller touchscreen to view the current alarm list.
  • Check the heat pump isolator switch and the consumer-unit breaker/RCD for the heat pump are ON (do not repeatedly reset a tripping breaker).

What the engineer will check

  • Check the heat pump has power and isolator is ON.
  • Check connection and polarity of Modbus wires between wiring centre and heat pump (s3.12).
  • Check Smart flow sensor connection to wiring centre.
  • Check flow sensor configuration (Appendix E).
  • Check the heat pump is working correctly.

Who to ask for: Heating controls installer / Grant-trained engineer.

What you might notice

What owners and engineers report

9 owner and engineer reports mention this.

  • No heating on the Aerona³ R32: 5 reports
  • No hot water on the Aerona³ R32: 4 reports

Sources

A code explains what the controller detected, not a confirmed root cause.