ELCO heat pump error codes

ELCO · A niche brand in the UK. 110 codes across 2 product families, each taken from the manufacturer’s manuals. ELCO technical support ↗

Find a ELCO engineer →110 codes · reviewed 23 September 2026

Filter by product family

Type the code on your display or a word from its meaning. Each code opens its own page with what it means, whether it is safe and what you can check.

110 codes

CodeMeaningStops?Homeowner check?
1E0
EEPROM error - main board
YesYes
1E5
Condenser temperature probe T3A fault
YesYes
1Eb
Antifreeze probe Taf1 fault
YesYes
1Ed
Compressor discharge temperature probe A fault
YesYes
1EE
Refrigerant temperature probe T6A fault
YesYes
1F0
IPM module transmission error (A)
YesYes
1F3
Fan A transmission error
YesYes
1F4
Protection L0 or L1 intervened 3 times in 60 minutes (circuit A)
YesYes
1F6
Circuit A bus voltage (PTC)
YesYes
1F9
Radiator (heat sink) temperature sensor Tfin1 fault
YesYes
1FF
Fan A fault
YesYes
1H9
Compressor driver A - configuration error
YesYes
1HE
Expansion valve A error
YesYes
1PP
IPM module error, circuit A
YesYes
1PU
Fan A module error
YesYes
2E0
EEPROM error - inverter A module
YesYes
2E5
Condenser temperature probe T3B fault
YesYes
2Eb
Antifreeze probe Taf2 fault
YesYes
2Ed
Compressor discharge temperature probe B fault
YesYes
2EE
Refrigerant temperature probe T6B fault
YesYes
2F0
IPM module transmission error (B)
YesYes
2F3
Fan B transmission error
YesYes
2F4
Protection L0 or L1 intervened 3 times in 60 minutes (circuit B)
YesYes
2F6
Circuit B bus voltage (PTC)
YesYes
2F9
Radiator (heat sink) temperature sensor Tfin2 fault
YesYes
2FF
Fan B fault
YesYes
2H9
Compressor driver B - configuration error
YesYes
2HE
Expansion valve B error
YesYes
2P2
Thermal cleanse (anti-legionella) not complete
NoYes
2P3
DHW boost: comfort setpoint not reached
NoYes
2P4
First thermostat of resistance (auto) tripped
NoYes
2P5
Second thermostat of resistance (manual) tripped
NoYes
2P6
Night tariff contact not present
NoYes
2P7
Precirculation error
YesYes
2P8
HP temperature out of range
NoYes
2PP
IPM module error, circuit B
YesYes
2PU
Fan B module error
YesYes
3E0
EEPROM error - inverter B module
YesYes
3F3
Fan C transmission error
YesYes
3FF
Fan C fault
YesYes
3HE
Expansion valve C error
YesYes
3PU
Fan C module error
YesYes
114
Outdoor sensor damaged
YesYes
420
Bus supply overload
YesYes
701
Zone 1 flow (send) probe damaged
YesYes
702
Zone 2 flow probe damaged
YesYes
703
Zone 3 flow probe damaged (N/A)
YesYes
711
Zone 1 return probe damaged
YesYes
712
Zone 2 return probe damaged
YesYes
713
Zone 3 return probe damaged (N/A)
YesYes
722
Zone 2 overheat
YesYes
723
Zone 3 overheat (N/A)
YesYes
902
System flow sensor damaged
YesYes
903
System return sensor damaged
YesYes
910
HP communication error (RS 485)
YesYes
923
Heating circuit pressure error
YesYes
924
Communication error (e-BUS 2)
YesYes
933
Overheat (>90 °C)
YesYes
934
DHW tank sensor damaged
YesYes
935
Tank overtemperature (>85 °C)
YesYes
936
Floor thermostat 1 error (ST1)
YesYes
937
No circulation error
YesYes
938
Anode fault
NoYes
939
HP (heat pump) error
YesYes
940
Hydraulic scheme not defined
YesYes
941
Night tariff contact not defined
YesYes
942
Load shedding contact not defined
YesYes
C7
PL (module high temperature) occurred 3 times
YesYes
d0
Gate error (d0 and address displayed alternately every 10 s)
YesYes
dF
Defrosting
NoNo
E1
Phase sequence - control from main board
YesYes
E2
Communication error between main board and keypad
YesYes
E3
Total outlet water temperature probe Tw fault (master unit only)
YesYes
E4
Outlet water temperature probe Two fault
YesYes
E6
Storage (DHW) temperature probe T5 fault
YesYes
E7
Room (outdoor air) temperature probe T4 fault
YesYes
E8
Phase sequence protection
YesYes
E9
No water flow (manual reset) - drained system
YesYes
EC
Slave unit module reduction (communication)
YesYes
EF
Return water temperature probe fault
YesYes
EH
Autotest error
YesYes
EP
Discharge temperature probe fault
YesYes
EU
Condenser total temperature probe Tz fault
YesYes
F2
Insufficient superheat (overheating)
YesYes
Fb
Pressure sensor fault
YesYes
Fd
Return (suction) air temperature sensor fault
YesYes
FE
Recovery temperature sensor fault
YesYes
FP
DIP switch for modular unit configuration error
YesYes
H5
High / low voltage
YesYes
L0
Inverter module protection
YesYes
L1
Low voltage protection
YesYes
L2
High voltage protection
YesYes
L4
MCE error (inverter drive)
YesYes
L5
Speed 0 (compressor zero speed)
YesYes
L7
No phase (compressor phase loss)
YesYes
L8
Frequency variation higher than 15 Hz
YesYes
L9
Phase frequency difference higher than 15 Hz
YesYes
P0
High pressure / discharge temperature protection
YesYes
P1
Low pressure protection
YesYes
P2
Total condenser output high temperature Tz
YesYes
P4
Compressor A in protection (current)
YesYes
P6
Module error
YesYes
P7
Condenser high temperature
YesYes
P9
Inlet/outlet water temperature difference
YesYes
Pb
Winter antifreeze protection
NoNo
PC
Evaporator low pressure in cooling
YesYes
PE
Antifreeze protection - evaporator low temperature in cooling
YesYes
PF
Circuit board lock - controller lock/unlock error
YesYes
PH
High room (outdoor air) temperature T4
NoYes
PL
Tfin module high temperature
YesYes