F43-F47 on a Dimplex A-Class air source heat pump: F43-F47 error messages are defrost errors (A-Class controller)

Short answer

On a Dimplex heat pump, F43-F47 means: F43-F47 error messages are defrost errors (A-Class controller). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: F43-F47 error messages are defrost errors (A-Class controller).

Part involved: Defrost / condenser plate heat exchanger.

When it shows: Service-menu note: heating water return >= 18C required for proper defrost.

Likely causes:

  • Defrost failure; water flow temperature too low (condenser plate heat exchanger may freeze).

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Manual reset: If a major fault occurs many times the compressor locks out: power to the compressor must be off at least 2 minutes and back on (Issue 1.05 p.31).

What you can check

  • Read the error code from the message list (login 998 > Message list) and give it to the installer.
  • Check the outdoor unit is not blocked by snow or debris.
  • Check the system pressure gauge reading.

What the engineer will check

  • Check return temperature >= 18C during defrost.
  • Check flow rate, strainer, buffer isolation.
  • Manual defrost only by trained installers.

Who to ask for: heat pump service engineer.

Certification: F-Gas (refrigerant handling) certification for any refrigerant-circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026