F32Dimplex · WPM heat pump manager platform (error-code grouping)

F32 on a Dimplex WPM heat pump manager platform: Warm up: if the minimum oil temperature is not reached after 9 hours, the warm up error is triggered

Short answer

On a Dimplex heat pump, F32 means: Warm up: if the minimum oil temperature is not reached after 9 hours, the warm up error is triggered. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Warm up: if the minimum oil temperature is not reached after 9 hours, the warm up error is triggered.

Part involved: Crank case heater.

When it shows: Minimum oil temperature not reached within 9 h.

Likely causes:

  • Crank case heater faulty or not powered.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: After rectifying the fault the heat pump can be restarted; switching off the control voltage also acknowledges the fault (WPM Touch p.54). On text-display WPMs press Esc to acknowledge (EconPlus EN-16).

Manual reset: Acknowledge after rectification.

What you can check

  • Note the fault code, the heat pump model (type plate) and controller software version shown in operating data, and contact the installer/Dimplex service.

What the engineer will check

  • Check crank case heater.

Who to ask for: heat pump service engineer.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.