F30 on a Dimplex WPM heat pump manager platform: Hot gas thermostat fault
Short answer
On a Dimplex heat pump, F30 means: Hot gas thermostat fault. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Hot gas thermostat fault.
Part involved: Hot gas thermostat.
Likely causes:
- Hot gas thermostat tripped or faulty.
- Wrong coding when no hot gas thermostat fitted (GDHV).
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: After rectifying the fault the heat pump can be restarted; switching off the control voltage also acknowledges the fault (WPM Touch p.54). On text-display WPMs press Esc to acknowledge (EconPlus EN-16).
Manual reset: Acknowledge after rectification.
What you can check
- Note the fault code, the heat pump model (type plate) and controller software version shown in operating data, and contact the installer/Dimplex service.
What the engineer will check
- Inform after-sales service.
- F-Gas engineer to check hot gas thermostat switching temperature (value from Dimplex Technical Services).
- Verify coding number.
Who to ask for: refrigeration engineer.
Certification: F-Gas (refrigerant handling) certification for any refrigerant-circuit work.
What you might notice