F2 on a Dimplex WPM heat pump manager platform: Extension N17.2: 'Active cooling' extension module not detected

Short answer

On a Dimplex heat pump, F2 means: Extension N17.2: 'Active cooling' extension module not detected. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Extension N17.2: 'Active cooling' extension module not detected.

Part involved: N17.2 active cooling extension module.

Likely causes:

  • Connecting line interrupted/plug loose/lines mixed up.
  • No power supply to module.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: After rectifying the fault the heat pump can be restarted; switching off the control voltage also acknowledges the fault (WPM Touch p.54). On text-display WPMs press Esc to acknowledge (EconPlus EN-16).

Manual reset: Acknowledge after rectification.

What you can check

  • Note the fault code, the heat pump model (type plate) and controller software version shown in operating data, and contact the installer/Dimplex service.

What the engineer will check

  • Check connecting line to extension/module: line interrupted, plug loose, individual lines mixed up.
  • Check power supply to the module.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026