SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Dimplex
F10Dimplex · WPM heat pump manager platform (error-code grouping)

F10 on a Dimplex WPM heat pump manager platform: WPIO extension: refrigeration circuit controller not detected

Short answer

On a Dimplex heat pump, F10 means: WPIO extension: refrigeration circuit controller not detected. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: WPIO extension: refrigeration circuit controller not detected.

Part involved: WPIO extension / refrigeration circuit controller.

Likely causes:

  • Connecting line interrupted/plug loose/lines mixed up.
  • No power supply.
  • Outdoor unit switched off or breaker tripped (GDHV).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: After rectifying the fault the heat pump can be restarted; switching off the control voltage also acknowledges the fault (WPM Touch p.54). On text-display WPMs press Esc to acknowledge (EconPlus EN-16).

Manual reset: Acknowledge after rectification.

What you can check

  • Check the outdoor unit's isolator switch is ON.
  • Check the consumer unit breaker for the heat pump is on (reset once only).
  • Look for obvious external cable damage without touching.
  • Note the fault code, the heat pump model (type plate) and controller software version shown in operating data, and contact the installer/Dimplex service.

What the engineer will check

  • Check connecting line to extension/module: line interrupted, plug loose, individual lines mixed up.
  • Check power supply to the module.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.