SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Baxi
H06.66Baxi · HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

H06.66 on a Baxi HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP: HP gas temp Heat pump gas temperature sensor error

Short answer

On a Baxi heat pump, H06.66 means: HP gas temp Heat pump gas temperature sensor error. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: HP gas temp Heat pump gas temperature sensor error.

Part involved: temperature sensor.

Likely causes:

  • Check the sensor resistance The connector for sensor T2B is loose. Reconnect it. The connector for sensor T2B is wet or contains water. Drain the water and dry the connector. Add a waterproof adhesive. Sensor T2B is faulty, replace it with a new sensor.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - system restarts automatically when the cause disappears (may run in degraded/back-up mode meanwhile).

Manual reset: not required once cause removed.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • The manual's user steps allow switching the system off and on once to see if the error clears; if the code returns, contact the installer.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

  • Check the sensor resistance The connector for sensor T2B is loose. Reconnect it. The connector for sensor T2B is wet or contains water. Drain the water and dry the connector. Add a waterproof adhesive. Sensor T2B is faulty, replace it with a new sensor.

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026