E00.00Baxi

E00.00 on a Baxi heat pump: TFlow Open Flow temperature sensor is either removed or measures a temperature below range

Short answer

On a Baxi heat pump, E00.00 means: TFlow Open Flow temperature sensor is either removed or measures a temperature below range. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

On the Assure Split ASHP (AWHP 4.5/6/8 MR + Assure AWHP-IDU 4-8 E)

The manual says: TFlow Open Flow temperature sensor is either removed or measures a temperature below range.

Part involved: temperature sensor.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: TFlow Open Flow temperature sensor is either removed or measures a temperature below range.

Part involved: temperature sensor.

Likely causes:

  • Poor sensor connection: Check the wiring between the PCB and the sensor Check that the sensor has been correctly fitted Sensor failure: Check the Ohmic value of the sensor Replace the sensor if necessary.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Remove cause, then acknowledge the error manually on the user interface (engineer).

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • The manual's user steps allow switching the system off and on once to see if the error clears; if the code returns, contact the installer.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Split ASHP (AWHP 4.5/6/8 MR + Assure AWHP-IDU 4-8 E)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Poor sensor connection: Check the wiring between the PCB and the sensor Check that the sensor has been correctly fitted Sensor failure: Check the Ohmic value of the sensor Replace the sensor if necessary.

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026