ODU1-3F on an Atlantic heat pump: Pressure sensor error

Short answer

On an Atlantic heat pump, ODU1-3F means: Pressure sensor error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

The manual says: Pressure sensor error.

Likely causes:

  • Refrigerant circuit protection (pressure/temperature out of range).

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

The manual says: Faulty evaporator temperature sensor.

Likely causes:

  • Temperature sensor short-circuit, open circuit, unplugged or faulty.

Is it safe?

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

  • Check the outdoor unit is not blocked by leaves, debris or snow.
  • Note the error number/LED pattern shown and give it to your installer.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

  • Note the error number/LED pattern shown and give it to your installer.

What the engineer will check

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

  • Check refrigerant charge and leaks, expansion valve, pressure sensor/switch and airflow.
  • Check water flow through the plate heat exchanger.

Who to ask for: refrigeration (F-gas).

Certification: F-gas certification for refrigerant work.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

  • Check sensor wiring and connector.
  • Measure sensor resistance; replace if faulty.

Who to ask for: heat pump / electrical.