ODU1-13F on an Atlantic heat pump: Current trip (permanent stoppage)

Short answer

On an Atlantic heat pump, ODU1-13F means: Current trip (permanent stoppage). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

The manual says: Current trip (permanent stoppage).

Likely causes:

  • Power supply abnormality or outdoor/indoor PCB, inverter or IPM fault.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

The manual says: Compressor rotor position not detected.

Likely causes:

  • Compressor start/position detection or motor control fault.

Is it safe?

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

  • Check the heat pump isolator and consumer-unit breakers are on (do not open any casing).
  • Note the error number/LED pattern shown and give it to your installer.
  • If breakers trip repeatedly, leave the unit off and call an engineer.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

  • Check the heat pump isolator and consumer-unit breakers are on (do not open any casing).
  • Note the error number/LED pattern shown and give it to your installer.

What the engineer will check

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

  • Check supply voltage, PCB, inverter/IPM/PFC components and connectors.

Who to ask for: electrical / heat pump.

Certification: Qualified electrician / heat pump engineer.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

  • Check compressor wiring, windings and inverter/IPM board.

Who to ask for: refrigeration / electrical.

Certification: Electrical competence; F-gas if compressor replacement.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026