Heat pumps · Error codes · Atlantic
AOYA30-7Atlantic · Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)
AOYA30-7 on an Atlantic Alféa Hybrid Duo: Abnormal discharge (back-flow) temperature
Short answer
On an Atlantic heat pump, AOYA30-7 means: Abnormal discharge (back-flow) temperature. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Abnormal discharge (back-flow) temperature.
Likely causes:
- Refrigerant circuit protection (pressure/temperature out of range).
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
What you can check
- Check the outdoor unit is not blocked by leaves, debris or snow.
- Note the error number/LED pattern shown and give it to your installer.
What the engineer will check
- Check refrigerant charge and leaks, expansion valve, pressure sensor/switch and airflow.
- Check water flow through the plate heat exchanger.
Who to ask for: refrigeration (F-gas).
Certification: F-gas certification for refrigerant work.
Sources
- alféa hybrid duo Installation and commissioning instructions (doc 1440-13) ↗ · 1440-13 · page 66 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026