441 on an Atlantic heat pump: 2nd zone sensor not configured (if 2nd circuit kit); set parameter 5700 to 2, 4 or 6 (BX31)

Short answer

On an Atlantic heat pump, 441 means: 2nd zone sensor not configured (if 2nd circuit kit); set parameter 5700 to 2, 4 or 6 (BX31). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

The manual says: 2nd zone sensor not configured (if 2nd circuit kit); set parameter 5700 to 2, 4 or 6 (BX31).

Part involved: BX31.

Likely causes:

  • Sensor input BX3x not configured or sensor fault (e.g. 2nd zone sensor with 2nd circuit kit).

On the Alféa Excellia A.I. / Excellia Duo A.I. (R410A split, 11-16)

The manual says: BX31 no function.

Likely causes:

  • Short-circuit.
  • Unplugged or disconnected sensor.
  • Faulty sensor.
  • Sensor input BX3x not configured or sensor fault (e.g. 2nd zone sensor with 2nd circuit kit).

On the Alféa Extensa A.I. / Extensa Duo A.I. R32 (split, 3-10)

The manual says: BX31 no function.

Likely causes:

  • Short-circuit.
  • Unplugged or disconnected sensor.
  • Faulty sensor.
  • Sensor input BX3x not configured or sensor fault (e.g. 2nd zone sensor with 2nd circuit kit).

On the Alféa Extensa + / Extensa Duo + (R410A split, 5-16)

The manual says: 2nd zone sensor not configured (if 2nd circuit kit); set parameter 5700 to 2, 4 or 6 (BX31).

Part involved: BX31.

Likely causes:

  • Sensor input BX3x not configured or sensor fault (e.g. 2nd zone sensor with 2nd circuit kit).

Is it safe?

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: 1.

On the Alféa Excellia A.I. / Excellia Duo A.I. (R410A split, 11-16)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

On the Alféa Extensa A.I. / Extensa Duo A.I. R32 (split, 3-10)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

On the Alféa Extensa + / Extensa Duo + (R410A split, 5-16)

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: 1.

What you can check

  • Note the error number/LED pattern shown and give it to your installer.

What the engineer will check

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

  • Set the BX3x input parameter (e.g. line 5700) or check the sensor wiring.

Who to ask for: heat pump controls.

On the Alféa Excellia A.I. / Excellia Duo A.I. (R410A split, 11-16)

  • Check the sensor's wiring.
  • Replace the sensor.

Who to ask for: heat pump controls.

On the Alféa Extensa A.I. / Extensa Duo A.I. R32 (split, 3-10)

  • Check the sensor's wiring.
  • Replace the sensor.

Who to ask for: heat pump controls.

On the Alféa Extensa + / Extensa Duo + (R410A split, 5-16)

  • Set the BX3x input parameter (e.g. line 5700) or check the sensor wiring.

Who to ask for: heat pump controls.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.