127 on an Atlantic heat pump: Anti-legionella temperature not reached

Short answer

On an Atlantic heat pump, 127 means: Anti-legionella temperature not reached. The heat pump keeps running. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 5 sources

What it means

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

The manual says: Anti-legionella temperature not reached.

Likely causes:

  • Anti-legionella temperature setpoint not reached.

On the Alféa Excellia A.I. / Excellia Duo A.I. (R410A split, 11-16)

The manual says: Legionella temp.

Likely causes:

  • Anti-legionella temperature setpoint not reached.

On the Alféa Extensa A.I. / Extensa Duo A.I. R32 (split, 3-10)

The manual says: Legionella temp.

Likely causes:

  • Anti-legionella temperature setpoint not reached.

On the Alféa Extensa + / Extensa Duo + (R410A split, 5-16)

The manual says: Anti-legionella temperature not reached.

Likely causes:

  • Anti-legionella temperature setpoint not reached.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

The manual says: Anti-legionella temperature not reached.

Likely causes:

  • Anti-legionella temperature setpoint not reached.

Is it safe?

On the Alféa Excellia / Excellia Duo (R410A split, 11-16, pre-A.I.)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: 1.

On the Alféa Excellia A.I. / Excellia Duo A.I. (R410A split, 11-16)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

On the Alféa Extensa A.I. / Extensa Duo A.I. R32 (split, 3-10)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

On the Alféa Extensa + / Extensa Duo + (R410A split, 5-16)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: 1.

On the Alféa Hybrid Duo (heat pump + integrated fuel-oil boiler)

Does the heat pump stop?No
SeverityWarning
Engineer needed?Yes

The heat pump keeps running.

What you can check

  • Note the error number/LED pattern shown and give it to your installer.

What the engineer will check

  • Check wiring and operation of the DHW electric backup / boiler connection.

Who to ask for: heating / electrical.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.