SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Ariston
2P5Ariston · NIMBUS NET R32 control platform (shared error list)

2P5 on an Ariston NIMBUS NET R32 control platform: Electric heater thermostat (automatic reset)

Short answer

On an Ariston heat pump, 2P5 means: Electric heater thermostat (automatic reset). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Electric heater thermostat (automatic reset).

Part involved: backup heater safety thermostat (auto reset).

Likely causes:

  • Main circulation pump not activating.
  • Low flow.
  • Safety thermostat condition / cabling.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

What you can check

  • Note the error code shown on the Sensys HD interface and contact the installer / Ariston service.

What the engineer will check

  • Check activation of the main circulation pump.
  • Check the flow via flow meter reading (parameter 13.9.3).
  • Check the safety thermostat and cabling.

Who to ask for: heat pump controls / hydronics.

Certification: Competent heating engineer; electrical competence for wiring checks.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026