796 on an alpha innotec heat pump: Safety switch off: Safety input triggered; manual reset required. Case 1 inverter malfunction; case 2 high-pressure pressostats triggered; case 3 (LWDV/Hybrox only) voltage fluctuations beyond standard

Short answer

On an alpha innotec heat pump, 796 means: Safety switch off: Safety input triggered; manual reset required. Case 1 inverter malfunction; case 2 high-pressure pressostats triggered; case 3 (LWDV/Hybrox only) voltage fluctuations beyond standard. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Safety switch off: Safety input triggered; manual reset required. Case 1 inverter malfunction; case 2 high-pressure pressostats triggered; case 3 (LWDV/Hybrox only) voltage fluctuations beyond standard.

When it shows: Safety input triggered; manual reset required. Case 1 inverter malfunction; case 2 high-pressure pressostats triggered; case 3 (LWDV/Hybrox only) voltage fluctuations beyond standard.

Likely causes:

  • Inverter malfunction.
  • High-pressure pressostat triggered.
  • LWDV/Hybrox: supply voltage fluctuations.

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: manual reset by installer/authorised service required.

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).

What the engineer will check

  • Case 1: check inverter.
  • Case 2: check heating water throughflow, overflow, flow temperature sensor and high-pressure sensor.
  • Case 3: unit must be turned off and re-secured manually.

Who to ask for: heat pump / heating engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.