769 on an alpha innotec heat pump: Pump control: No valid flow signal from the circulating pump. Reset autom
Short answer
On an alpha innotec heat pump, 769 means: Pump control: No valid flow signal from the circulating pump. Reset autom. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Pump control: No valid flow signal from the circulating pump. Reset autom.
When it shows: No valid flow signal from the circulating pump. Reset autom.
Likely causes:
- Pump load/control cable wiring.
- Circulating pump fault.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: yes.
Manual reset: automatic.
What you can check
- Note the error number and text shown on the Luxtronik display.
- The controller resets this automatically after the stated time - wait for the automatic restart before calling.
- Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
- Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).
What the engineer will check
- Check load and control cable wiring of circulation pump.
- Check circulating pump.
Who to ask for: heat pump / heating engineer.