Heat pumps · Error codes · alpha innotec
765alpha innotec · alpha innotec, all models

765 on an alpha innotec heat pump: Suction gas Overheating (SSH): Suction gas superheat outside limits (above/below 2 K) for longer than 5 minutes. Auto reset after 5 minutes or manual; repeated occurrences permanently block the refrigerant circuit

Short answer

On an alpha innotec heat pump, 765 means: Suction gas Overheating (SSH): Suction gas superheat outside limits (above/below 2 K) for longer than 5 minutes. Auto reset after 5 minutes or manual; repeated occurrences permanently block the refrigerant circuit. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Suction gas Overheating (SSH): Suction gas superheat outside limits (above/below 2 K) for longer than 5 minutes. Auto reset after 5 minutes or manual; repeated occurrences permanently block the refrigerant circuit.

When it shows: Suction gas superheat outside limits (above/below 2 K) for longer than 5 minutes. Auto reset after 5 minutes or manual; repeated occurrences permanently block the refrigerant circuit.

Likely causes:

  • Superheat control problem in refrigerant circuit.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: automatic.

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • The controller resets this automatically after the stated time - wait for the automatic restart before calling.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).

What the engineer will check

  • If repeated: refrigerant circuit blocked - call authorised service (AS).

Who to ask for: F-gas certified refrigeration / heat pump engineer (R290 flammable-refrigerant competence for propane units such as LWD).

Certification: F-gas certification (R407C/R410A units); flammable refrigerant training for R290 units.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026