Heat pumps · Error codes · alpha innotec
726alpha innotec · alpha innotec, all models

726 on an alpha innotec heat pump: Sensor mixing circ 1. Please call installer: Break or short circuit in the mixing circuit 1 sensor

Short answer

On an alpha innotec heat pump, 726 means: Sensor mixing circ 1. Please call installer: Break or short circuit in the mixing circuit 1 sensor. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Sensor mixing circ 1. Please call installer: Break or short circuit in the mixing circuit 1 sensor.

When it shows: Break or short circuit in the mixing circuit 1 sensor.

Likely causes:

  • Mixing circuit sensor defective.
  • Plug/cable fault.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no.

Manual reset: manual acknowledgement required (rotary pushbutton 7 s) - display usually says "Please call installer".

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).

What the engineer will check

  • Check mixing circuit sensor, plug and connection line.

Who to ask for: heat pump service engineer (electrical/controls).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026