Heat pumps · Error codes · alpha innotec
721alpha innotec · alpha innotec, all models

721 on an alpha innotec heat pump: Low-pressure switch-off. Reset autom.: Low-pressure pressostat or sensor in the refrigerant circuit has responded; automatic restart after some time (brine/water and water/water)

Short answer

On an alpha innotec heat pump, 721 means: Low-pressure switch-off. Reset autom.: Low-pressure pressostat or sensor in the refrigerant circuit has responded; automatic restart after some time (brine/water and water/water). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low-pressure switch-off. Reset autom.: Low-pressure pressostat or sensor in the refrigerant circuit has responded; automatic restart after some time (brine/water and water/water).

When it shows: Low-pressure pressostat or sensor in the refrigerant circuit has responded; automatic restart after some time (brine/water and water/water).

Likely causes:

  • Pressostat switching point.
  • Low flow on heat source side.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: automatic.

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • The controller resets this automatically after the stated time - wait for the automatic restart before calling.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).
  • Read the brine circuit pressure gauge if one is visible and report it; brine refilling is an installer task.

What the engineer will check

  • Check switching point of the pressostat.
  • Check flow on heat source side.

Who to ask for: F-gas certified refrigeration / heat pump engineer (R290 flammable-refrigerant competence for propane units such as LWD).

Certification: F-gas certification (R407C/R410A units); flammable refrigerant training for R290 units.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026