714 on an alpha innotec heat pump: Hot gas SW. Reset in hh:mm: Thermal application limit of the heat pump reached during DHW; domestic hot water off for hh:mm. Only triggers while compressor running

Short answer

On an alpha innotec heat pump, 714 means: Hot gas SW. Reset in hh:mm: Thermal application limit of the heat pump reached during DHW; domestic hot water off for hh:mm. Only triggers while compressor running. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Hot gas SW. Reset in hh:mm: Thermal application limit of the heat pump reached during DHW; domestic hot water off for hh:mm. Only triggers while compressor running.

When it shows: Thermal application limit of the heat pump reached during DHW; domestic hot water off for hh:mm. Only triggers while compressor running.

Likely causes:

  • DHW flow problem.
  • DHW heat exchanger.
  • DHW temperature too high for application limit.
  • Circulation pump.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: automatic.

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • The controller resets this automatically after the stated time - wait for the automatic restart before calling.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).

What the engineer will check

  • Check flow of domestic hot water.
  • Check heat exchanger.
  • Check DHW temperature and circulation pump.

Who to ask for: heat pump / heating engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.