Heat pumps · Error codes · alpha innotec
704alpha innotec · alpha innotec, all models

704 on an alpha innotec heat pump: Error hot gas. Reset in hh:mm: Maximum hot-gas (discharge) temperature in the refrigerant circuit exceeded; automatic restart after the displayed time

Short answer

On an alpha innotec heat pump, 704 means: Error hot gas. Reset in hh:mm: Maximum hot-gas (discharge) temperature in the refrigerant circuit exceeded; automatic restart after the displayed time. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Error hot gas. Reset in hh:mm: Maximum hot-gas (discharge) temperature in the refrigerant circuit exceeded; automatic restart after the displayed time.

When it shows: Maximum hot-gas (discharge) temperature in the refrigerant circuit exceeded; automatic restart after the displayed time.

Likely causes:

  • Low refrigerant quantity.
  • Evaporation problem.
  • Superheat.
  • Flow/return conditions.
  • Heat source minimum.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: yes.

Manual reset: automatic.

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • The controller resets this automatically after the stated time - wait for the automatic restart before calling.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).

What the engineer will check

  • Check refrigerant quantity.
  • Check evaporation and superheat.
  • Check flow, return and HS-min.

Who to ask for: F-gas certified refrigeration / heat pump engineer (R290 flammable-refrigerant competence for propane units such as LWD).

Certification: F-gas certification (R407C/R410A units); flammable refrigerant training for R290 units.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026