Heat pumps
Heat pumps · Error codes · alpha innotec
703alpha innotec · alpha innotec, all models

703 on an alpha innotec heat pump: Antifreeze. Please call installer: Air/water units only: heat pump running and flow temperature < 5 °C - frost danger detected

Short answer

On an alpha innotec heat pump, 703 means: Antifreeze. Please call installer: Air/water units only: heat pump running and flow temperature < 5 °C - frost danger detected. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Antifreeze. Please call installer: Air/water units only: heat pump running and flow temperature < 5 °C - frost danger detected.

When it shows: Air/water units only: heat pump running and flow temperature < 5 °C - frost danger detected.

Likely causes:

  • Insufficient heat pump output.
  • Defrost valve fault.
  • Heating system problem.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: manual acknowledgement required (rotary pushbutton 7 s) - display usually says "Please call installer".

What you can check

  • Note the error number and text shown on the Luxtronik display.
  • Acknowledge the message by pressing the rotary pushbutton for about 7 seconds (as the Luxtronik manual permits); if the same error reappears, contact your installer or ait customer service with the error number.
  • Check the heat pump breakers/isolator at the consumer unit are on (do not open any casing).
  • Air source units: check the outdoor unit/air inlet and outlet are not blocked by snow, ice, leaves or debris.
  • Check the heating system pressure gauge reading and report it to the installer.

What the engineer will check

  • Check heat pump output.
  • Check defrost valve.
  • Check heating system.

Who to ask for: heat pump / heating engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026