F10 on a Warmflow heat pump: AC Power Overvoltage Error

Short answer

On a Warmflow heat pump, F10 means: AC Power Overvoltage Error. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Zeno R290 air source heat pump AS01-R290/AS02-R290/AS03-R290

The manual says: AC Power Overvoltage Error.

Part involved: compressor driver / inverter board.

Likely causes:

  • The input voltage reading is incorrect/out of range.

On the Zeno A-Series air source heat pump (R32) AS01-R32/AS02-R32/AS03-R32

The manual says: DSP and PFC Communication Error.

Part involved: controller/PCB communication.

Likely causes:

  • There is a communication error between the DSP and the PFC.

On the Zeno A-Series air source heat pump (R410A) AS01/AS02/AS03

The manual says: DSP and PFC Communication Error.

Part involved: controller/PCB communication.

Likely causes:

  • There is a communication error between the DSP and the PFC.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

What you can check

On the Zeno R290 air source heat pump AS01-R290/AS02-R290/AS03-R290

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).

On the Zeno A-Series air source heat pump (R32) AS01-R32/AS02-R32/AS03-R32

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the controller display is lit and showing the code.

On the Zeno A-Series air source heat pump (R410A) AS01/AS02/AS03

  • Note the exact code shown on the controller (a photo helps) and report it to your installer or the manufacturer's service line.
  • Check the heat pump's supply breaker/isolator at the consumer unit is on (do not open any casing).
  • Check the controller display is lit and showing the code.

What the engineer will check

On the Zeno R290 air source heat pump AS01-R290/AS02-R290/AS03-R290

  • Check the input voltage measurement is above 265V (as printed).

Who to ask for: heat pump electrical / inverter.

Certification: Electrical competence; manufacturer-trained heat pump engineer.

On the Zeno A-Series air source heat pump (R32) AS01-R32/AS02-R32/AS03-R32

  • Check the wiring and connection between the DSP and the PFC.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

On the Zeno A-Series air source heat pump (R410A) AS01/AS02/AS03

  • Check the wiring and connection between the DSP and the PFC.

Who to ask for: heat pump controls / electrical.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

What owners and engineers report

3 owner and engineer reports mention this.

  • Controller / thermostat problem on the Zeno R290 air source heat pump AS01-R290/AS02-R290/AS03-R290: 1 report
  • Controller / thermostat problem on the Zeno A-Series air source heat pump (R32) AS01-R32/AS02-R32/AS03-R32: 1 report
  • Keeps stopping / cutting out on the Zeno A-Series air source heat pump (R32) AS01-R32/AS02-R32/AS03-R32: 1 report

Sources

A code explains what the controller detected, not a confirmed root cause.