S.272 on a Vaillant heat pump: Building circuit: Remaining feed head limit active The remaining feed head that is set under the configuration is reached

Short answer

On a Vaillant heat pump, S.272 means: Building circuit: Remaining feed head limit active The remaining feed head that is set under the configuration is reached. The heat pump keeps running with some functions stopped. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the aroTHERM plus (VWL ../6 A)

The manual says: Building circuit: Remaining feed head limit active The remaining feed head that is set under the configuration is reached.

Part involved: Heat pump control (status/Live Monitor).

When it shows: Building circuit: Remaining feed head limit active The remaining feed head that is set under the configuration is reached.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

On the flexoTHERM exclusive (VWF ../4)

The manual says: Building circuit: Remaining feed heads limit active.

Part involved: Heat pump control (status/Live Monitor).

When it shows: See official description.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

On the geoTHERM mini (VWS 30/4, VWS 36/4.1)

The manual says: Building circuit: Remaining feed heads limit active.

Part involved: Heat pump control (status/Live Monitor).

When it shows: See official description.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

Is it safe?

Does the heat pump stop?Partly
SeverityInformation only
Engineer needed?No

The heat pump keeps running with some functions stopped.

Resetting itself: yes - status changes automatically with operating state.

Manual reset: not applicable.

What you can check

  • Operating status only - no action needed. If heating or hot water is not being delivered for a long period, note the status code and tell your installer.

What the engineer will check

  • None required unless heating/hot water is not delivered; then review status history, settings and application limits.

Who to ask for: Vaillant-trained heat pump installer/engineer (MCS-certified installer).

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

What owners and engineers report

6 owner and engineer reports mention this.

  • Keeps stopping / cutting out on the aroTHERM plus (VWL ../6 A): 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.