Heat pumps · Error codes · Vaillant
S.255Vaillant

S.255 on a Vaillant heat pump: Fan unit 1: Air inlet temp. too high The compressor does not start because the outdoor temperature at the fan is above the application limits. Heating mode: > 43 °C. Domestic hot water mode: > 43 °C. Cooling mode: > 46 °C

Short answer

On a Vaillant heat pump, S.255 means: Fan unit 1: Air inlet temp. too high The compressor does not start because the outdoor temperature at the fan is above the application limits. Heating mode: > 43 °C. Domestic hot water mode: > 43 °C. Cooling mode: > 46 °C. The heat pump keeps running with some functions stopped. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the aroTHERM plus (VWL ../6 A)

The manual says: Fan unit 1: Air inlet temp. too high The compressor does not start because the outdoor temperature at the fan is above the application limits. Heating mode: > 43 °C. Domestic hot water mode: > 43 °C. Cooling mode: > 46 °C.

Part involved: Heat pump control (status/Live Monitor).

When it shows: Fan unit 1: Air inlet temp. too high The compressor does not start because the outdoor temperature at the fan is above the application limits. Heating mode: > 43 °C. Domestic hot water mode: > 43 °C. Cooling mode: > 46 °C.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

On the flexoTHERM exclusive (VWF ../4)

The manual says: Fan unit 1: Air inlet temp. too high.

Part involved: Heat pump control (status/Live Monitor).

When it shows: See official description.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

Is it safe?

Does the heat pump stop?Partly
SeverityInformation only
Engineer needed?No

The heat pump keeps running with some functions stopped.

Resetting itself: yes - status changes automatically with operating state.

Manual reset: not applicable.

What you can check

  • Operating status only - no action needed. If heating or hot water is not being delivered for a long period, note the status code and tell your installer.

What the engineer will check

  • None required unless heating/hot water is not delivered; then review status history, settings and application limits.

Who to ask for: Vaillant-trained heat pump installer/engineer (MCS-certified installer).

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • Intermittent fault on the aroTHERM plus (VWL ../6 A): 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026