S.240 on a Vaillant heat pump: Compr. oil temp. too low, environment too cold The compressor heating is switched on. The unit does not start up

Short answer

On a Vaillant heat pump, S.240 means: Compr. oil temp. too low, environment too cold The compressor heating is switched on. The unit does not start up. The heat pump keeps running with some functions stopped. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the aroTHERM plus (VWL ../6 A)

The manual says: Compr. oil temp. too low, environment too cold The compressor heating is switched on. The unit does not start up.

Part involved: Heat pump control (status/Live Monitor).

When it shows: Compr. oil temp. too low, environment too cold The compressor heating is switched on. The unit does not start up.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

On the flexoTHERM exclusive (VWF ../4)

The manual says: Compr. oil temp. too low, environment too cold.

Part involved: Heat pump control (status/Live Monitor).

When it shows: See official description.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

On the geoTHERM mini (VWS 30/4, VWS 36/4.1)

The manual says: Oil temperature too low.

Part involved: Heat pump control (status/Live Monitor).

When it shows: See official description.

Likely causes:

  • Operating status reported by the heat pump control (not a fault in itself).

Is it safe?

Does the heat pump stop?Partly
SeverityInformation only
Engineer needed?No

The heat pump keeps running with some functions stopped.

Resetting itself: yes - status changes automatically with operating state.

Manual reset: not applicable.

What you can check

  • Operating status only - no action needed. If heating or hot water is not being delivered for a long period, note the status code and tell your installer.

What the engineer will check

  • None required unless heating/hot water is not delivered; then review status history, settings and application limits.

Who to ask for: Vaillant-trained heat pump installer/engineer (MCS-certified installer).

Certification: MCS installer certification; Vaillant product training recommended.

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026