F.737Vaillant

F.737 on a Vaillant heat pump: Condensation temperature too high

Short answer

On a Vaillant heat pump, F.737 means: Condensation temperature too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

On the aroTHERM plus (VWL ../6 A)

The manual says: Condensation temperature too high.

Part involved: Condensation temperature too high.

Likely causes:

  • Temperature in the environment circuit (cooling mode) or building circuit (heating mode) too high for compressor operation; Feed-in of external heat into the building circuit; Refrigerant circuit overfilled; Insufficient flow rate in the building circuit.

On the flexoTHERM exclusive (VWF ../4)

The manual says: Condensation temperature too high.

Part involved: Condensation temperature too high.

Likely causes:

  • Temperature in the building circuit (heating mode) or environment circuit (cooling mode) too high for compressor operation; Refrigerant volume too high.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

On the aroTHERM plus (VWL ../6 A)

  • Note the full code and text shown on the display (and the date/time it appeared). Check the outdoor unit's air inlet and outlet are not blocked by leaves, debris, snow or ice build-up and clear any loose debris from around it (do not open the casing, poke the fins or use tools). The operating instructions allow the reset button on the indoor unit (or a reset via the system control) to be pressed once; if the code returns, do not keep resetting - contact your installer or Vaillant. If you smell gas/solvent near the outdoor unit or hear hissing, switch the heat pump off at the isolator, keep ignition sources away and call an engineer.

On the flexoTHERM exclusive (VWF ../4)

  • Note the full code and text shown on the display (and the date/time it appeared). Check the outdoor unit's air inlet and outlet are not blocked by leaves, debris, snow or ice build-up and clear any loose debris from around it (do not open the casing, poke the fins or use tools). Do not keep resetting the unit; report the code to your installer (the operating instructions for this product were not checked for a homeowner reset procedure). If you smell gas/solvent near the outdoor unit or hear hissing, switch the heat pump off at the isolator, keep ignition sources away and call an engineer.

What the engineer will check

On the aroTHERM plus (VWL ../6 A)

  • Reduce or stop the external heat that is entering; Check the back-up heater (heats up even though it is off in the sensor/actuator test?); Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test); Check the compressor outlet sensor, compressor outlet temperature sensor (TT135) and high-pressure sensor; Check the refrigerant filling volume for overfilling; Check whether the service valves on the outdoor unit are open; Check the air volume flow in cooling mode for sufficient flow rate; Checking the heating pump; Check the building circuit flow rate.

Who to ask for: F-gas certified refrigeration engineer with heat pump experience (R290 flammable-refrigerant competence required for aroTHERM plus / GeniaAir).

Certification: F-gas Category I (Regulation (EU) 517/2014 as retained in GB) certificate; flammable (R290) refrigerant training for R290 units.

On the flexoTHERM exclusive (VWF ../4)

  • Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test); Check the compressor inlet sensor, high-pressure sensor and low-pressure sensor; Check the refrigerant volume (see Technical data).

Who to ask for: F-gas certified refrigeration engineer with heat pump experience (R290 flammable-refrigerant competence required for aroTHERM plus / GeniaAir).

Certification: F-gas Category I (Regulation (EU) 517/2014 as retained in GB) certificate; flammable (R290) refrigerant training for R290 units.

What you might notice

What owners and engineers report

14 owner and engineer reports mention this.

  • No heating on the aroTHERM plus (VWL ../6 A): 8 reports
  • Keeps stopping / cutting out on the aroTHERM plus (VWL ../6 A): 6 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026