F.726Vaillant · geoTHERM mini (VWS 30/4, VWS 36/4.1)

F.726 on a Vaillant geoTHERM mini: Compressor protector switch opened

Short answer

On a Vaillant heat pump, F.726 means: Compressor protector switch opened. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor protector switch opened.

Part involved: Compressor protector switch opened.

Likely causes:

  • Compressor overheated, e.g. as a result of operating outside of its application limits; Maximum environmental temperature of 40 °C exceeded for the heat pump; Compressor blocked due to mechanical defect; Compressor blocked because the pressure difference is too high when switched on (> 3 bar); Environmental temperatures fall below 40 °C.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. Do not keep resetting the unit; report the code to your installer (the operating instructions for this product were not checked for a homeowner reset procedure).

What the engineer will check

  • Check the pressure difference during the start-up attempt.

Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).

Certification: Competent electrician (BS 7671 / Part P) for supply-side work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026