F.1191 on a Vaillant aroTHERM plus: Heat generator 1 communication interrupted (can be heat generator 1 to 8)

Short answer

On a Vaillant heat pump, F.1191 means: Heat generator 1 communication interrupted (can be heat generator 1 to 8). The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Heat generator 1 communication interrupted (can be heat generator 1 to 8).

Part involved: sensoCOMFORT system control / eBUS modules (FM3 = VR 70, FM5 = VR 71).

Likely causes:

  • Cable defective; incorrect plug connection (eBUS to heat pump/heat generator).

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: yes - message clears when communication/configuration is restored.

Manual reset: not normally required; configuration corrected by installer.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Check the system control display is lit; if it is dark or frozen, hold the top-right button for more than 5 seconds to restart it, or switch the heat generator's mains switch off for about 1 minute and back on (sensoCOMFORT operating instructions). If the message persists, inform your competent person.

What the engineer will check

  • Replace the cable; check the plug connection.

Who to ask for: Heat pump/controls installer familiar with Vaillant eBUS controls.

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

What owners and engineers report

25 owner and engineer reports mention this.

  • Controller / thermostat problem on the aroTHERM plus (VWL ../6 A): 12 reports
  • No heating on the aroTHERM plus (VWL ../6 A): 8 reports
  • No hot water on the aroTHERM plus (VWL ../6 A): 5 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026