F.1118 on a Vaillant flexoTHERM exclusive: Compressor: Incorrect phase seq
Short answer
On a Vaillant heat pump, F.1118 means: Compressor: Incorrect phase seq. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Compressor: Incorrect phase seq.
Part involved: Incorrect phase seq.
Likely causes:
- Incorrect order of phase connection to the grid feed-in; In-rush current limiter defective or incorrectly connected.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: no - the fault remains displayed until the cause is eliminated.
Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.
What you can check
- Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. Do not keep resetting the unit; report the code to your installer (the operating instructions for this product were not checked for a homeowner reset procedure).
What the engineer will check
- Change the phase order by switching over two phases at a time to the grid feed-in; Check the in-rush current limiter.
Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).
Certification: Competent electrician (BS 7671 / Part P) for supply-side work.
What you might notice
Sources
- flexoTHERM exclusive VWF 57/4 - 197/4 400V installation and maintenance instructions ↗ · 0020213394_05 · page flexoTHERM 400 V 0020213394_05 p.56; flexoTHERM 230 V 0020213395_04 p.50 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026