F.1117 on a Vaillant heat pump: Compressor: Phase failure
Short answer
On a Vaillant heat pump, F.1117 means: Compressor: Phase failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 2 sources
What it means
On the aroTHERM plus (VWL ../6 A)
The manual says: Compressor: Phase failure.
Part involved: Phase failure.
Likely causes:
- Defective fuse; Incorrect electrical connections; Mains voltage too low; Compressor/low tariff power supply not connected; Energy supply company lockout for longer than three hours.
On the flexoTHERM exclusive (VWF ../4)
The manual says: Compressor: Phase failure.
Part involved: Phase failure.
Likely causes:
- In-rush current limiter defective or incorrectly connected; Defective fuse; Poorly tightened electrical connections; Mains voltage too low; Compressor/low tariff power supply not connected; Blocked by energy supply company for over three hours.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: no - the fault remains displayed until the cause is eliminated.
Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.
What you can check
On the aroTHERM plus (VWL ../6 A)
- Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. The operating instructions allow the reset button on the indoor unit (or a reset via the system control) to be pressed once; if the code returns, do not keep resetting - contact your installer or Vaillant.
On the flexoTHERM exclusive (VWF ../4)
- Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. Do not keep resetting the unit; report the code to your installer (the operating instructions for this product were not checked for a homeowner reset procedure).
What the engineer will check
On the aroTHERM plus (VWL ../6 A)
- Check the fuse; Checking the electrical connections; Check the voltage at the heat pump electrical connection; Reduce energy supply company anti-cycling time to under three hours.
Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).
Certification: Competent electrician (BS 7671 / Part P) for supply-side work.
On the flexoTHERM exclusive (VWF ../4)
- Check the fuse; Check the electrical connections; Measure voltage at the heat pump electrical connection; Reduce energy supply company anti-cycling time to under three hours.
Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).
Certification: Competent electrician (BS 7671 / Part P) for supply-side work.
What you might notice
What owners and engineers report
15 owner and engineer reports mention this.
- No heating on the aroTHERM plus (VWL ../6 A): 8 reports
- No hot water on the aroTHERM plus (VWL ../6 A): 5 reports
- Heat pump will not start on the aroTHERM plus (VWL ../6 A): 2 reports
Sources
- Heat pump control interface module (VWZ AI) operating and installation instructions ↗ · 0020291573_01 · page VWZ AI appliance interface 0020291573_01 p.37; uniTOWER VIH QW 190/6 E 0020291525_05 p.63; aroTHERM split hydraulic station VWL ../5 IS 0020257319_05 p.61 · Reviewed 23 September 2026
- flexoTHERM exclusive VWF 57/4 - 197/4 400V installation and maintenance instructions ↗ · 0020213394_05 · page flexoTHERM 400 V 0020213394_05 p.56; flexoTHERM 230 V 0020213395_04 p.50 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026