F.1117 on a Vaillant heat pump: Compressor: Phase failure

Short answer

On a Vaillant heat pump, F.1117 means: Compressor: Phase failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

On the aroTHERM plus (VWL ../6 A)

The manual says: Compressor: Phase failure.

Part involved: Phase failure.

Likely causes:

  • Defective fuse; Incorrect electrical connections; Mains voltage too low; Compressor/low tariff power supply not connected; Energy supply company lockout for longer than three hours.

On the flexoTHERM exclusive (VWF ../4)

The manual says: Compressor: Phase failure.

Part involved: Phase failure.

Likely causes:

  • In-rush current limiter defective or incorrectly connected; Defective fuse; Poorly tightened electrical connections; Mains voltage too low; Compressor/low tariff power supply not connected; Blocked by energy supply company for over three hours.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

On the aroTHERM plus (VWL ../6 A)

  • Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. The operating instructions allow the reset button on the indoor unit (or a reset via the system control) to be pressed once; if the code returns, do not keep resetting - contact your installer or Vaillant.

On the flexoTHERM exclusive (VWF ../4)

  • Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. Do not keep resetting the unit; report the code to your installer (the operating instructions for this product were not checked for a homeowner reset procedure).

What the engineer will check

On the aroTHERM plus (VWL ../6 A)

  • Check the fuse; Checking the electrical connections; Check the voltage at the heat pump electrical connection; Reduce energy supply company anti-cycling time to under three hours.

Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).

Certification: Competent electrician (BS 7671 / Part P) for supply-side work.

On the flexoTHERM exclusive (VWF ../4)

  • Check the fuse; Check the electrical connections; Measure voltage at the heat pump electrical connection; Reduce energy supply company anti-cycling time to under three hours.

Who to ask for: Heat pump engineer with electrical competence (qualified electrician for supply/phase faults).

Certification: Competent electrician (BS 7671 / Part P) for supply-side work.

What you might notice

What owners and engineers report

15 owner and engineer reports mention this.

  • No heating on the aroTHERM plus (VWL ../6 A): 8 reports
  • No hot water on the aroTHERM plus (VWL ../6 A): 5 reports
  • Heat pump will not start on the aroTHERM plus (VWL ../6 A): 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026