CONNECTION-FAULT-HEAT-PUMPVaillant · aroTHERM

CONNECTION-FAULT-HEAT-PUMP on a Vaillant aroTHERM: Connection fault: Heat pump

Short answer

On a Vaillant heat pump, CONNECTION-FAULT-HEAT-PUMP means: Connection fault: Heat pump. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Connection fault: Heat pump.

Part involved: VWZ AI interface / eBUS.

Likely causes:

  • The eBUS connection between the heat pump and the VWZ AI heat pump control interface module is defective.

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: no - the fault remains displayed until the cause is eliminated.

Manual reset: yes - after the cause is eliminated, press the reset button (indoor unit) or reset via the system control; if it recurs after several resets contact customer service.

What you can check

  • Note the full code and text shown on the display (and the date/time it appeared). Check the heat pump supply breaker/isolator (and back-up heater breaker, if separate) at the consumer unit is on; if a breaker has tripped more than once, leave it off and call an engineer - do not open any casing. Do not keep resetting the unit; report the code to your installer (the operating instructions for this product were not checked for a homeowner reset procedure).

What the engineer will check

  • Check display-to-main-PCB connection in VWZ AI; check eBUS cable, polarity and supply between heat pump and VWZ AI.

Who to ask for: Heat pump/controls installer familiar with Vaillant eBUS controls.

Certification: MCS installer certification; Vaillant product training recommended.

What you might notice

What owners and engineers report

2 owner and engineer reports mention this.

  • No heating on the aroTHERM: 2 reports

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026