H91 on a Panasonic heat pump: Tank heater OLP abnormality

Short answer

On a Panasonic heat pump, H91 means: Tank heater OLP abnormality. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Tank heater OLP abnormality.

Part involved: Tank (booster/immersion) heater overload protector (OLP).

When it shows: During operation of tank booster heater, and tank booster heater OLP open circuit. Service-manual table judgement: Continue for 60 sec. (L, K, J MDC, J MXC, J AIO, H, F, E, D5, D8, C).

Likely causes:

  • 1 Faulty connector connection. 2 Faulty tank booster heater overload protector (OLP). 3 Faulty indoor unit PCB (main).

Is it safe?

Switch the heat pump off at its isolator and call an engineer.

Does the heat pump stop?Partly
SeveritySafety lockout
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Not stated in the Panasonic documents opened; protection counters lock out after the stated number of occurrences.

Manual reset: User: 'Error Reset' in the remote-controller Quick Menu (H/J/K/L controllers) or OFF/ON; engineer must clear the underlying cause (service manuals: 'When error happens, the power has to be reset').

What you can check

  • Read and note the code shown blinking on the remote controller (also stored under System Check > Error history). Per the Panasonic operating instructions the user may switch the system OFF/ON at the remote controller and use 'Error Reset' in the Quick Menu; if the code returns, leave the system and contact the installer (UK user guide lists Panasonic technical support as the fallback). Check the heat pump circuit breaker(s)/isolator at the consumer unit are ON (a tripped breaker is listed in the operating instructions' checks); if a breaker keeps tripping, leave it off and call an engineer.

What the engineer will check

  • Isolate power; check tank heater supply, connectors and OLP; identify overheating cause before resetting cylinder/heater thermal cut-out; check indoor PCB.

Who to ask for: Heat pump engineer with electrical competence.

Certification: Electrical work to BS 7671 by a competent person; F-gas certification if the refrigerant circuit is opened.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026