H22 on a Panasonic heat pump: Abnormal tank 2 sensor
Short answer
On a Panasonic heat pump, H22 means: Abnormal tank 2 sensor. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Abnormal tank 2 sensor.
Part involved: Tank 2 temperature sensor.
When it shows: When tank connection is set to ON, the temperature detected by the tank 2 sensor is used to determine sensor error. Service-manual table judgement: Continue for 5 sec. (L, marked not applicable for WH-SDC0509L).
Likely causes:
- 1 Faulty connector connection. 2 Faulty sensor. 3 Faulty indoor unit PCB (main).
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — needs a manual reset once the cause is fixed |
| Engineer needed? | Yes |
The heat pump keeps running with some functions stopped.
Resetting itself: Not stated in the Panasonic documents opened; protection counters lock out after the stated number of occurrences.
Manual reset: User: 'Error Reset' in the remote-controller Quick Menu (H/J/K/L controllers) or OFF/ON; engineer must clear the underlying cause (service manuals: 'When error happens, the power has to be reset').
What you can check
- Read and note the code shown blinking on the remote controller (also stored under System Check > Error history). Per the Panasonic operating instructions the user may switch the system OFF/ON at the remote controller and use 'Error Reset' in the Quick Menu; if the code returns, leave the system and contact the installer (UK user guide lists Panasonic technical support as the fallback).
What the engineer will check
- Check tank 2 sensor connector and resistance; check tank connection setting; replace sensor or indoor PCB.
Who to ask for: Heat pump engineer (Panasonic-trained).
Certification: None statutory; safe electrical isolation competence required.
What you might notice
Sources
- Service Manual Hydromodule WH-SDC0509L3E5/L6E5 with WH-WDG05LE5/07LE5/09LE5 (Order No PAPAMY2307068CE) ↗ · PAPAMY2307068CE · page 189 (error codes table, marked *); 195 (self-diagnosis) · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026