F36 on a Panasonic heat pump: Outdoor air temperature sensor abnormality

Short answer

On a Panasonic heat pump, F36 means: Outdoor air temperature sensor abnormality. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Outdoor air temperature sensor abnormality.

Part involved: Outdoor air temperature sensor.

When it shows: During startup and operation of cooling and heating, the temperatures detected by the outdoor air temperature sensor are used to determine sensor error. Service-manual table judgement: Continue for 5 sec. (L, K, J MDC, J MXC, J AIO, H, F, E, D5, D8, C).

Likely causes:

  • 1 Faulty connector connection. 2 Faulty sensor. 3 Faulty outdoor unit PCB (main).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in the Panasonic documents opened; protection counters lock out after the stated number of occurrences.

Manual reset: User: 'Error Reset' in the remote-controller Quick Menu (H/J/K/L controllers) or OFF/ON; engineer must clear the underlying cause (service manuals: 'When error happens, the power has to be reset').

What you can check

  • Read and note the code shown blinking on the remote controller (also stored under System Check > Error history). Per the Panasonic operating instructions the user may switch the system OFF/ON at the remote controller and use 'Error Reset' in the Quick Menu; if the code returns, leave the system and contact the installer (UK user guide lists Panasonic technical support as the fallback).

What the engineer will check

  • Check outdoor air temperature sensor connector and resistance; replace sensor or outdoor PCB.

Who to ask for: Heat pump engineer (Panasonic-trained).

Certification: None statutory; safe electrical isolation competence required.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.