SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Panasonic
F27Panasonic · Panasonic, all models

F27 on a Panasonic heat pump: Pressure switch abnormality

Short answer

On a Panasonic heat pump, F27 means: Pressure switch abnormality. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Pressure switch abnormality.

Part involved: Outdoor high pressure switch.

When it shows: During compressor stop, and outdoor high pressure switch is remain opened. Service-manual table judgement: Continue for 1 min. (L, K, J MDC, J MXC, J AIO, H, F, E, D5, D8, C).

Likely causes:

  • 1 Faulty connector connection. 2 Faulty switch. 3 Faulty outdoor unit PCB (main).

Is it safe?

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in the Panasonic documents opened; protection counters lock out after the stated number of occurrences.

Manual reset: User: 'Error Reset' in the remote-controller Quick Menu (H/J/K/L controllers) or OFF/ON; engineer must clear the underlying cause (service manuals: 'When error happens, the power has to be reset').

What you can check

  • Read and note the code shown blinking on the remote controller (also stored under System Check > Error history). Per the Panasonic operating instructions the user may switch the system OFF/ON at the remote controller and use 'Error Reset' in the Quick Menu; if the code returns, leave the system and contact the installer (UK user guide lists Panasonic technical support as the fallback).

What the engineer will check

  • Check pressure switch connector and continuity (switch remaining open while compressor stopped); replace switch or outdoor PCB.

Who to ask for: F-gas certified refrigeration / heat pump engineer (Panasonic-trained).

Certification: UK F-gas certification (Category I) for any refrigerant-circuit work; flammable-refrigerant competence for R32 (J/K) and R290 (L/M) units.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026