SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Ochsner
Er57Ochsner · OTE 3 / OTE 4 controller fault platform (error-code grouping)

Er57 on an Ochsner OTE 3 / OTE 4 controller fault platform: Heat source frost protection. Cause/remedy per manual: Insufficient heat source energy, source temperature too low: Check heat source, check heat source pump, clean water filter, submersible pump faulty

Short answer

On an Ochsner heat pump, Er57 means: Heat source frost protection. Cause/remedy per manual: Insufficient heat source energy, source temperature too low: Check heat source, check heat source pump, clean water filter, submersible pump faulty. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Heat source frost protection. Cause/remedy per manual: Insufficient heat source energy, source temperature too low: Check heat source, check heat source pump, clean water filter, submersible pump faulty.

Part involved: Heat source frost protection.

Likely causes:

  • Insufficient heat source energy.
  • source temperature too low.
  • check heat source pump.
  • clean water filter.
  • submersible pump faulty.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Heat pump restarts automatically when the safety assembly re-enables it; 2 automatic acknowledgements allowed (manual 17.2).

Manual reset: Up to 3 manual acknowledgements via ESC > ERROR menu > setting button (manual 17.2.1).

What you can check

  • Note the Er number and text (ESC on main screen opens the alarm menu) and contact your OCHSNER system partner.
  • The manual allows the user to try acknowledging an ERROR once via the ESC menu; if it returns, leave it and call the installer.

What the engineer will check

  • Check heat source, check heat source pump, clean water filter, submersible pump faulty.

Who to ask for: OCHSNER customer service / authorised service partner (manual: ERROR faults only remedied by OCHSNER or authorised partners).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026