Er38Ochsner · OTE 3 / OTE 4 controller fault platform (error-code grouping)

Er38 on an Ochsner OTE 3 / OTE 4 controller fault platform: Hot gas. Cause/remedy per manual: Expansion valve, insufficient refrigerant, target value too high Check refrigerant circuit Contact OCHSNER Customer Service

Short answer

On an Ochsner heat pump, Er38 means: Hot gas. Cause/remedy per manual: Expansion valve, insufficient refrigerant, target value too high Check refrigerant circuit Contact OCHSNER Customer Service. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Hot gas. Cause/remedy per manual: Expansion valve, insufficient refrigerant, target value too high Check refrigerant circuit Contact OCHSNER Customer Service.

Part involved: Hot gas.

Likely causes:

  • Expansion valve.
  • insufficient refrigerant.
  • target value too high.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: Heat pump restarts automatically when the safety assembly re-enables it; 2 automatic acknowledgements allowed (manual 17.2).

Manual reset: Up to 3 manual acknowledgements via ESC > ERROR menu > setting button (manual 17.2.1).

What you can check

  • Note the Er number and text (ESC on main screen opens the alarm menu) and contact your OCHSNER system partner.
  • The manual allows the user to try acknowledging an ERROR once via the ESC menu; if it returns, leave it and call the installer.

What the engineer will check

  • Check refrigerant circuit.
  • Contact OCHSNER Customer Service.

Who to ask for: OCHSNER customer service / authorised service partner (manual: ERROR faults only remedied by OCHSNER or authorised partners).

Certification: F-gas certification for refrigerant circuit work.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026