Heat pumps · Error codes · NIBE
916NIBE · NIBE, all models

916 on a NIBE heat pump: Sensor fault: BT16 evaporator sensor (exhaust air module): BT16 in exhaust air module unreasonable value for longer than 2 s

Short answer

On a NIBE heat pump, 916 means: Sensor fault: BT16 evaporator sensor (exhaust air module): BT16 in exhaust air module unreasonable value for longer than 2 s. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Sensor fault: BT16 evaporator sensor (exhaust air module): BT16 in exhaust air module unreasonable value for longer than 2 s.

Part involved: fans, air filters, air sensors.

When it shows: BT16 in exhaust air module unreasonable value for longer than 2 s.

Likely causes:

  • Open circuit or short circuit on sensor input; defective sensor.

Is it safe?

Does the heat pump stop?Not stated
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: yes - Automatic reset after 60 s communication.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the exhaust air valves/grilles in the rooms are open and not blocked; check the filter reminder in the user manual maintenance section.

What the engineer will check

  • Check ventilation airflow, fans, filters, air sensors and condensate drainage/level monitor. NIBE lists: Open circuit or short circuit on sensor input; defective sensor.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.