Heat pumps · Error codes · NIBE
617NIBE · NIBE, all models

617 on a NIBE heat pump: Temperature protection compressor activated: 2 repeated FQ alarms within 2.5 hours

Short answer

On a NIBE heat pump, 617 means: Temperature protection compressor activated: 2 repeated FQ alarms within 2.5 hours. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Temperature protection compressor activated: 2 repeated FQ alarms within 2.5 hours.

Part involved: compressor discharge (hot gas).

When it shows: 2 repeated FQ alarms within 2.5 hours.

Likely causes:

  • S2125: Poor heating medium flow; lack of refrigerant; S2125-16/-20: FQ14.1 compressor peak 130 C, FQ14.2 compressor intake 75 C.

Is it safe?

Does the heat pump stop?Partly
SeveritySafety lockout
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - not stated.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Air source systems: check the outdoor unit is clear of leaves/snow/ice. Read the heating system pressure gauge and note the reading for your installer.

What the engineer will check

  • Check discharge sensor BT14 mounting, refrigerant charge and circuit (F-gas qualified), airflow over evaporator and heating medium flow. NIBE lists: Poor heating medium flow; lack of refrigerant; S2125-16/-20: FQ14.1 compressor peak 130 C, FQ14.2 compressor intake 75 C.

Who to ask for: Heat pump engineer with F-gas qualification (NIBE-trained / NIBE PRO installer).

Certification: F-gas certification for refrigerant circuit work (plus flammable-refrigerant competence for R290/R32 models).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.