Heat pumps · Error codes · NIBE
60NIBE · NIBE, all models

60 on a NIBE heat pump: Low HTF out: Outgoing brine temperature below set minimum and alarm selected as permanent [other NIBE documents: Outgoing brine below set minimum and alarm set permanent]

Short answer

On a NIBE heat pump, 60 means: Low HTF out: Outgoing brine temperature below set minimum and alarm selected as permanent [other NIBE documents: Outgoing brine below set minimum and alarm set permanent]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low HTF out: Outgoing brine temperature below set minimum and alarm selected as permanent [other NIBE documents: Outgoing brine below set minimum and alarm set permanent].

Part involved: brine pump, brine sensors, level monitor.

When it shows: Outgoing brine temperature below set minimum and alarm selected as permanent; Outgoing brine below set minimum and alarm set permanent.

Likely causes:

  • Poor circulation in brine circuit: check brine pump, bleeding and brine freezing point.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer.

What the engineer will check

  • Check brine circuit: bleeding, brine pump, brine freezing point/concentration, brine sensors and level monitor/pressure switch; look for brine leaks. NIBE lists: Poor circulation in brine circuit: check brine pump, bleeding and brine freezing point.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.