SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · NIBE
583NIBE · NIBE, all models

583 on a NIBE heat pump: Low flow defrosting (slave EB102-EB108) (listed as range 582-588): Low flow during defrosting in one of EB102-EB108

Short answer

On a NIBE heat pump, 583 means: Low flow defrosting (slave EB102-EB108) (listed as range 582-588): Low flow during defrosting in one of EB102-EB108. The heat pump keeps running with some functions stopped.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low flow defrosting (slave EB102-EB108) (listed as range 582-588): Low flow during defrosting in one of EB102-EB108.

Part involved: evaporator defrost.

When it shows: Low flow during defrosting in one of EB102-EB108.

Likely causes:

  • Flow-related; clogged particle filter; defective circulation pump.

Is it safe?

Does the heat pump stop?Partly
SeverityWarning

The heat pump keeps running with some functions stopped.

Resetting itself: yes - Defrosting stops.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the outdoor unit is not blocked by leaves, snow or ice and that nothing obstructs the airflow.

What the engineer will check

  • Check system volume and flow during defrost, particle filter, circulation pump, evaporator airflow, evaporator/defrost sensors and refrigerant circuit. NIBE lists: Flow-related; clogged particle filter; defective circulation pump.

Who to ask for: NIBE-trained heat pump installer (NIBE PRO / VIP).

Certification: None specific beyond competent heat pump installer; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026