449 on a NIBE heat pump: Inverter alarm type II / failed compressor starts: Compressor ran below allowed minimum speed / failed to start 3 times within 2 hours or continuously for 1 hour [other NIBE documents: Compressor has not started when required 3 times within 2 h / Compressor ran at lower speed than permitted 3 times within 2 hours]

Short answer

On a NIBE heat pump, 449 means: Inverter alarm type II / failed compressor starts: Compressor ran below allowed minimum speed / failed to start 3 times within 2 hours or continuously for 1 hour [other NIBE documents: Compressor has not started when required 3 times within 2 h / Compressor ran at lower speed than permitted 3 times within 2 hours]. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Inverter alarm type II / failed compressor starts: Compressor ran below allowed minimum speed / failed to start 3 times within 2 hours or continuously for 1 hour [other NIBE documents: Compressor has not started when required 3 times within 2 h / Compressor ran at lower speed than permitted 3 times within 2 hours].

Part involved: inverter and compressor drive.

When it shows: Compressor ran below allowed minimum speed / failed to start 3 times within 2 hours or continuously for 1 hour; Compressor has not started when required 3 times within 2 h; Compressor ran at lower speed than permitted 3 times within 2 hours; Compressor does not start when required, 3 times within 2 hours.

Likely causes:

  • F2120: Unsuccessful start attempt; start fault, compressor; low voltage | F2120: Defective inverter; defective compressor | S2125: Defective inverter; defective compressor.

Is it safe?

Does the heat pump stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: no/unknown - Compressor blocked. Manual reset possible when alarm has disappeared; Compressor blocked.

Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains - NIBE: Compressor blocked. Manual reset possible when alarm has disappeared; Compressor blocked.

What you can check

  • Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.

What the engineer will check

  • Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Defective inverter; defective compressor; Unsuccessful start attempt; start fault, compressor; low voltage.

Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician.

Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026