432 on a NIBE heat pump: Inverter alarm type I (low phase voltage, temporary): Phase voltage to the inverter temporarily too low [other NIBE documents: Phase voltage to inverter too low]
Short answer
On a NIBE heat pump, 432 means: Inverter alarm type I (low phase voltage, temporary): Phase voltage to the inverter temporarily too low [other NIBE documents: Phase voltage to inverter too low]. The heat pump keeps running with some functions stopped.
Reviewed 23 September 2026 · 1 source
What it means
The manual says: Inverter alarm type I (low phase voltage, temporary): Phase voltage to the inverter temporarily too low [other NIBE documents: Phase voltage to inverter too low].
Part involved: inverter and compressor drive.
When it shows: Phase voltage to the inverter temporarily too low; Phase voltage to inverter too low.
Likely causes:
- F2120: Low voltage.
Is it safe?
| Does the heat pump stop? | Partly |
|---|---|
| Severity | Fault — clears by itself when the condition goes |
The heat pump keeps running with some functions stopped.
Resetting itself: yes - Compressor stopped; automatic reset 60 s after fault corrected; Stops the compressor.
Manual reset: Reset from the controller alarm menu ('reset alarm' / 'Reset alarm and try again'); alarm recurs if the cause remains.
What you can check
- Read the alarm text and the 'info/action' help on the controller display (VVM/SMO or S-series smartguide). NIBE's manuals let the homeowner select 'reset alarm' ('Reset alarm and try again' on S-series); if the lamp returns to normal the alarm has cleared. If it comes back, do not keep resetting: select 'aid mode' ('Auxiliary operation' on S-series) if offered, so any electric additional heat keeps heat/hot water going, and contact your installer. Check the heat pump and indoor unit breakers/RCD at the consumer unit are on; if one trips again, leave it off and call an engineer.
What the engineer will check
- Check main and group fuses and cable connections, supply voltage under load, inverter terminal blocks, inverter mounting/cooling paste, compressor wiring and compressor. NIBE lists: Low supply voltage; phase failure; Low voltage.
Who to ask for: NIBE-trained heat pump engineer and/or qualified electrician.
Certification: Electrical work to BS 7671 by a competent electrician (notifiable work under Part P in England & Wales).
What you might notice
Sources
- TECHNICAL INFORMATION - ALARM LIST SMO 40 (TIF EN 2042-1, M12658EN) ↗ · TIF EN 2042-1 M12658EN · page 19 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026